详细介绍: Select required orifice
diameter using the
graph below
Orifice Disc - Sizing Guide (mm)
Notes
This chart is calculated at 21.8
cSt and 49°C for ISO VG32 fluid
(DTE-24), values will change
with viscosity changes.
Note
To calculate orifice diameter at
other flows and differential pressures
use the following formula:
D=1.350 x √(Q/(√?P)
Note
where D= orifice diameter in
inches; Q= flow in US gallons
per minute; ?P= differential
pressure across orifice in bar.
J
J-52.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. .600
.500
.400
.350
.320
.300
.280
.270
.260
.250
.240
.230
.220
.210
.200
.190
.180
.170
.160
.150
.140
.130
.120
.110
.100
.090
.080
.070
.060
.050
.040
.030
.020
.010 |